Input Only Bug 11 HD (all versions) Bussing Bug?:(



If input only monitoring is enabled on a track and (this is key) and if the output on that track is another digital bus that is not mapped to an analog output in your i/o setup when editing, writing automation to all, or audio-suiting regions on other tracks that feed into the input only monitoring master track, the master track will receive signal (and you’ll see it on the meters) but sometimes there will be no audio sent to the digital bus on the output.



This doesn’t happen with every edit or writing automation but seems to occur the most frequently when audio-suiting / rendering files from a plugin. It’s frustrating because it doesn’t always occur and seemingly happens at random, perhaps 33% of the time in my experiece.



This means I can't digitally buss a track I am input monitoring through an output to an another aux track. The output on an input only monitoring track must be routed directly to your analog outputs.

Hopefully this helps someone else!